EasyManua.ls Logo

ToolKitRC M6AC - Other Functions

ToolKitRC M6AC
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
@ToolkiRC 2024
35
Other functions
1. Firmware upgrade
After connecting the M6AC to the computer with the
USB cable in the box, the computer will recognize a USB
drive named Toolkit. Download the upgrade file app.upg
from the official Toolkit RC website and overwrite the
files in the drive to upgrade the firmware.
2. USB output
Type -A USB supports 5.0V 1.0A output to charge
mobile devices.
3. Automatically continue charging/ discharging
When a battery is fully charged, connect the next
battery. The device will automatically continue to charge
and discharge, you can start and stop this function
under the settings menu
4. Fan level
When the internal temperature of the device reaches
40 degrees, the fan starts to work, the speed is increased
by the temperature linear control, and when AC input,
when the power input power is higher than 55W, the fan
works at full speed.
6. Manual voltage calibration
With the M6AC powered off, press and hold [ā—button].
without releasing, connect the power supply, and the
system will enter the manual voltage calibration mode.
Use a voltmeter to measure the actual voltage of each
battery, move the cursor to the corresponding voltage