input port when charging.
Max current: the maximum current drawn from the input
port during charging.
Min voltage: is the lowest allowable input voltage.
Charging safety settings: Work-related security settings.
As shown in the figure below.
Safe Inter. Temp.: above this temperature value, the
device will stop the main port output.
Safe time: the maximum time of continuous charging, it
will stop charging if it exceeds this.
Safe capacity: the maximum capacity for continuous
charging, and it will stop charging if exceeded.
Synchronous mode: After turning on this function, the
two channels can be combined with the main port to
charge the same battery, and the maximum current can
reach 50A.
Continuous Operation: After turning on the function,
remove the full charged battery, and after connecting