D4208-EN TMR4610 Operators Manual 27
11.5 Re-Use Recipe/Pen Data
Note: When re-using data stored in indicator, it takes recipe and pen information and
removes completed weights loaded or unloaded and marks them undone. It will accumulate
data day to day.
Download data to USB Drive before re-using recipe and pen data stored. D.A.N. 6214,
ERASFD Feature will erase the DONE feed-lines, when info is downloaded to the USB.
Note: For continuous re-use, set D.A.N. 6205 to on.
11.6 Mixer Time
The mix timer allows the operator to set a timer to alert the operator when the mixing is
completed. This can be manually entered or entered as part of the recipe using the TMR
TRACKER or other software package.
1. To re-use recipe/pen data enter D.A.N.
8201, then press .
On=Clear, Clear=Reuse, Net=exit
2. Press to reuse recipe/pen data.
1. Press .
2. Use the numeric keypad to enter the
amount of time.
3. Press .
4. The Mix Timer will begin to count
down. When it reaches zero the alarm
light and buzzer will turn on.
5. Press to enter the weighing mode.
6. Press the or key to re-enter
the batching mode.