52 TMR4610 Operators Manual D4208-EN
SETTING
[display]
D.A.N.
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
PEN TOLERANCE
(PTOLER)
6006
0
Enter value to accept pen as
completed.
BATCH
TOLERANCE
OVERLOCK
(BOVRLK)
6007
OFF, ON
If ON prevents auto-
advancing if preset exceeds
tolerance
BATCH ADVANCE
DELAY
(BDELAY)
6008
0, MANUAL
Select seconds to delay
before advancing to next
feed-line.
MANUAL PEN
ADVANCE
(MANPEN)
6009
OFF, ON
If ON -Overrides Automatic
advance for Pens.
INGREDIENT
STARTED WEIGHT
(ISTART)
6011
40 lbs.
This weight threshold
determines if the ingredient
has been started.
PEN WEIGHT
(PEN WT)
6012
LOAD, GROSS, NET
Select method for displaying
pen weight - Net, Load, or
Gross.
RESIZE RECIPE
(RESIZE)
6013
OFF, SELECT, LOAD, ANIMAL
If ON - operator can change
recipe size.
MENU 6.0.5-COMMON
BATCHING
RECIPE PRINT
FORMAT
(RECFMT)
6051
SYSTEM, AUTO, 32-TMR
Defines how scale will print
when in weighing mode or a
batch.
RECIPE TOTAL
(RECTOT)
6052
(SCALE)PROG, LAST,
PRGCOR, LSTCORON,
OFF(PC)
Selects Total amount to be
displayed when starting
recipe. D.A.N. 6054 select
PC or SCALE
INGREDIENT
RE-SIZING
(INGSIZ)
6053
(PC)OFF, 1 ING, 1+2ING, ----
(SCALE) OFF, 1ING, 1ING+P
Selects Automatic Ingredient
Re-Sizing mode. D.A.N. 6054
select PC or SCALE.
PROGRAM RECIPE
(PROGRAM)
6054
PC, SCALE
Selects program method, PC
or at SCALE.

Table of Contents