4 STANDARD MEASUREMENT MODE
4-7
4.2.4 Distance Measurement (Single/N-times Measurement)
When presetting the number of times, the instrument measures the distance as the setting times and
the average distance will be displayed. When presetting the number of times as 1, it does not display
the average distance, because of single measurement. It has been set at single measurement at fac-
tory.
1) Setting the number of times
Confirm the angle measurement mode.
2) Measuring Method
Confirm the angle measurement mode.
Operating procedure Operation Display
1
Press [F1](SD) or [F2](HD) key.
2
Press [F6](
) key to get the function page as
2.
[F2]
[F6]
3
Press [F3](MEAN) key.
[F3]
4
Input the setting the number of times, and
press [ENT] key. *1)
[Example] 4 times
N-times measurement starts.
[F4][ENT]
V : 90°10'20"
HR: 120°30'40"
SD HD NEZ 0SET HOLD P1
V : 90°10'20"
HR: 120°30'40" PSM 0.0
HD: PPM 0.0
VD: (m) F.R
MEAS MODE VH SD NEZ P1
REC SO MEAN m/ft P2
Average times
N:0
EXIT BS
V : 90°10'20"
HR: 120°30'40" PSM 0.0
HD: < PPM 0.0
VD: (m) *F.N
REC SO MEAN m/ft P2
1
Operating procedure Operation Display
1
Collimate the center of the prism.
Collimate
2
Select the measurement mode by pressing
[F1](SD) or [F2](HD) key.
Example: Horizontal distance
N-times measurement starts.
[F2]
V : 90°10'20"
HR: 120°30'40"
SD HD NEZ 0SET HOLD P1
V : 90°10'20"
HR: 120°30'40" PSM 0.0
HD: PPM 0.0
VD: (m) F.N
MEAS MODE VH SD NEZ P