EasyManua.ls Logo

Topcon IS01 - Checking;Adjusting the Cross-Hairs on Telescopic;Wide-Angle Images

Topcon IS01
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
123
7 CHECK AND ADJUSTMENT
7.3.5 Checking/Adjusting the Cross-Hairs on Telescopic/Wide-angle Images
Checking telescopic Image
1
Level the instrument with the plate level.
2
With the telescope, collimate target point A,
located at a distance of at least 15 meters.
3
Check that the telescopic image (magnification
of 1) is displayed. If the cross-hairs are
centered on point A, adjustment is not
necessary. If they are off-center, perform
adjustment as follows.
Adjustment
Prior to adjustment, carry out section 7.3.4“Collimation of the Instrument” .
1
With the telescope, collimate target point A,
located at a distance of at least 15 meters.
2
Press the [ADJUST] key.
3
Press the [NEXT] key.
4
Press the [CMOS SENSOR ADJUST] key.
A

Table of Contents

Related product manuals