EasyManua.ls Logo

Topcon RL-H2Sa - Laser Sensor Display Indicators

Topcon RL-H2Sa
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
Display (LS-70A/70B)
High precision mode
Normal precision mode
RL-H2Sa Height Alert warning *
The sensor will signal if the laser has been
disturbed so the height of the instrument
can be checked.
The buzzer will sound for about ve sec-
onds and the height alert warning symbol
will ash until the sensor detects normal
beam rotation from the laser. To obtain nor-
mal beam rotation, the RL-H2Sa must be
turned off then back on. Then check that
beam height has not changed (See page
16).
RL-H2Sa Battery warning *
The sensor will signal if the battery of the
RL-H2Sa is low. The laser low battery
warning symbol will ash on the LS-70 dis-
play. No audio signal is generated for this
warning.
Above grade indicator
Move the sensor down, The arrow will
become shorter as the on-grade position is
approached (see next page for specic
information).
Audio signal: High- pitch, frequent beep.
On-Grade indicator
(Audio signal: Continuous beep sound)
Below grade indicator
Move the sensor up, The arrow will become
shorter as the on-grade position is
approached (see next page for specic infor-
mation).
Audio signal: Lower- pitch, slower frequency.
Sensor battery indicator
Indicates the battery status of LS-70A/70B
as follows.
Flashing alternately
Battery is sufcient.
The power is low, but sensor is still usable.
Dead battery. Replace the 9v alkaline bat-
tery as instructed on next page.
*Warning detection at the LS-70 can be
canceled by turning off the LS-70, then
turning it back on while pressing the buzzer
sound switch.