EasyManua.ls Logo

Toro 4045 - Zap-Alert System Testing Procedure; Actions When Zap-Alert System is Triggered

Toro 4045
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TestingtheZap-alertSystem
TheZap-Alertsystemisanelectricstrikesensingdeviceon
themachinethattriggersastrobelightandaudiblealarmin
theeventthatthedrillbit,reamer,orstakebreaksintoan
energizedpowerline.Intheeventofanelectricstrike,the
machinewillbecomeenergized,settingoffthealarm.
DANGER
IftheZap-alertsystemactivateswhiledrilling,the
machine,exceptfortheoperatorplatform,will
becomeenergized.Ifyoustepofftheoperator
platformorifsomeonetouchesthemachineor
wetgroundnearthemachineorinthebore,you
ortheonewhotouchedthemachinecouldbe
electrocuted,causingseriousinjuryordeath.
TesttheZap-alertsystembeforedrilling.
Deploythegroundingstakebeforedrilling.
Ensurethatthestakeisfullyinsertedintomoist
soil.
IftheZap-alertistriggered:
Stayintheseatanddonottouchtheground
oranyotherpartofthemachineuntilthe
powerhasbeenturnedoff.Donotpour
liquidsorurinatefromtheoperatorplatform
ontotheground.
Stopdrilling,stopthedrilling-uidow,and
retractthedrilloutoftheground.
Keepeveryoneawayfromthemachine.
Keepstandingorrunningwateranddrilling
uidcontainedclosetothemachine.Keep
wateranddrillinguidsourcesawayfrom
thebrokenline.
Contacttheutilitycompanytohavepower
shutofftothebrokenline.Donotresetthe
Zap-alertsystemuntilthepowerhasbeen
turnedoff.
TesttheZap-alertsystembeforeusingthedrilleachday,as
follows:
1.Openthefronthood;refertoOpeningtheFront
Hood(page81).
2.Laythegroundingstakeatonthegroundawayfrom
themachine.Donotdrivethestakeintotheground.
Important:Donotallowthestaketotouchany
partofthemachine.
3.ConnectanalligatorclipfromtheZap-alerttesterto
thegroundingstudontheZap-alertsystem(Figure62).
Figure62
1.Testbutton5.Resetbutton
2.Zap-alerttester6.Alligatorclips
3.Zap-alertsystem7.Machinegroundingpoint
4.Zap-alertsystem
groundingstud
4.Connecttheotheralligatorcliptoametalcomponent
ofthemachineframe.
5.PresstheTestbuttonontheZap-alerttester(Figure
62).
TheZap-alertalarmshouldsound,andthestrobeon
topofthefronthoodshouldash.
6.PresstheZap-alertresetbuttontostopthealarm
(Figure62).