Loading...
HighViscosityIndex/LowPourPointAnti-wearHydraulic
Fluid,ISOVG46
MaterialProperties:
Viscosity,ASTMD445cSt@40°C44to50
cSt@100°C7.9to8.5
ViscosityIndexASTMD2270
140to160
PourPoint,ASTMD97-34°Fto-49°F
IndustrySpecications:
VickersI-286-S(QualityLevel),VickersM-2950-S
(QualityLevel),DenisonHF-0
Important:TheISOVG46Multigradeuidhas
beenfoundtoofferoptimalperformanceinawide
rangeoftemperatureconditions.Foroperation
inconsistentlyhighambienttemperatures,18°C
(65°F)to49°C(120°F),ISOVG68hydraulicuid
mayofferimprovedperformance.
PremiumBiodegradableHydraulicFluid-Mobil
EALEnviroSyn46H
Important:MobilEALEnviroSyn46Histheonly
syntheticbiodegradableuidapprovedbyToro.
Thisuidiscompatiblewiththeelastomersused
inTorohydraulicsystemsandissuitablefora
wide-rangeoftemperatureconditions.Thisuidis
compatiblewithconventionalmineraloils,butfor
maximumbiodegradabilityandperformancethe
hydraulicsystemshouldbethoroughlyushedof
conventionaluid.Theoilisavailablein19L(5
gallon)containersor55gallondrumsfromyour
MobilDistributor.
Important:Manyhydraulicuidsarealmost
colorless,makingitdifculttospotleaks.A
reddyeadditiveforthehydraulicsystemoilis
availablein20ml(2/3oz)bottles.Onebottleis
sufcientfor15-22L(4-6gallons)ofhydraulicoil.
Orderpartno.44-2500fromyourauthorizedToro
distributor.Thisreddyeisnotrecommendedfor
usewithbiodegradableuids.
Important:Regardlessofhydraulicuidtype
used,anymachineusedformowingfairways,
verticuttingorusedduringambienttemperatures
above29°C(85°F)shouldhaveOilCoolerKit,
PartNo.117-9314,installed.
FillingtheHydraulicTank
1.Positionthemachineonalevelsurface.
Note:Makesurethemachinehascooleddown
sotheoiliscold.
2.Removethecapfromthereservoir(Figure29).
g014719
Figure29
1.Hydraulicreservoircap
3.Slowlyllthereservoirwiththeappropriate
hydraulicuiduntilthelevelreachestheFull
markinthewhitewindowinthefrontofthe
reservior.Donotoverll.
Important:Topreventsystem
contamination,cleanthetopofthe
hydraulicuidcontainersbeforepuncturing.
Ensurethepourspoutandfunnelareclean.
4.Installthereservoircapandwipeupanyuid
thatmayhavespilled.
Important:Checklevelofhydraulicuid
beforeengineisrststartedanddaily
thereafter.
DrainingWaterfromthe
FuelFilter
ServiceInterval:Beforeeachuseordaily
1.Positionthemachineonalevelsurfaceandstop
theengine.
2.Placeadrainpanunderthefuellter.
3.Openthedrainplugonthefuellter
approximatelyoneturnanddrainany
accumulatedwater(Figure30).