WARNING
Batteryterminalsormetaltoolscouldshort
againstmetaltractorcomponentscausing
sparks.Sparkscancausethebatterygasses
toexplode,resultinginpersonalinjury.
Whenremovingorinstallingthebattery,
donotallowthebatteryterminalstotouch
anymetalpartsofthetractor.
Donotallowmetaltoolstoshortbetween
thebatteryterminalsandmetalpartsofthe
tractor.
WARNING
Incorrectbatterycableroutingcoulddamage
thetractorandcablescausingsparks.Sparks
cancausethebatterygassestoexplode,
resultinginpersonalinjury.
Ifcorrosionoccursattheterminals,
disconnectthecables,negative(-)cable
rst,andscrapetheclampsandterminals
separately.Reconnectthecables,positive
(+)cablerst,andcoattheterminalswith
petroleumjelly.
Alwaysdisconnectthenegative(black)
batterycablebeforedisconnectingthe
positive(red)cable.
Alwaysconnectthepositive(red)battery
cablebeforeconnectingthenegative
(black)cable.
StoringtheBattery
Ifthemachinewillbestoredmorethan30days,
removethebatteryandchargeitfully.Eitherstore
itontheshelfonthemachine.Leavethecables
disconnectedifitisstoredonthemachine.Store
thebatteryinacoolatmospheretoavoidquick
deteriorationofthechargeinthebattery.Toprevent
thebatteryfromfreezing,makesureitisfullycharged.
Thespecicgravityofafullychargedbatteryis
1.265–1.299.
LocatingtheFuses
Thefusesinthemachine’selectricalsystemare
locatedundertheseat(Figure46).
g014617
Figure46
1.Fuses
2.50Afuseforradiatorfan
(behindpartsillustrated)
FuseLayout
LiftReel
E-ReelEnable
OverT emp
7.5A
ReelEngage
Lights
Lift/Lower
LeakDetectorFan
15A7.5A
Start/Run
Starter
Diag.Lights
Glow
15A7.5A
Run
ECMLogic
Power
10A2A