EngineWarningMessages—SootAccumulation
IndicationLevel
FaultCode
EnginePowerRatingRecommendedAction
Level1:Engine
Warning
g213866
Figure37
CheckEngine
SPN3719,FMI16
Thecomputerde-ratesthe
enginepowerto85%
Performaparkedregeneration
assoonaspossible;referto
ParkedRegeneration(page43).
Level2:Engine
Warning
g213867
Figure38
CheckEngine
SPN3719,FMI0
Thecomputerde-ratesthe
enginepowerto50%
Performarecoveryregeneration
assoonaspossible;referto
RecoveryRegeneration
(page46).
39