5.TheInfoCenterdisplaystheINITIATINGDPF
REGENmessage(Figure63).
g224411
g227681
Figure63
6.TheInfoCenterdisplaysthetimetocomplete
message(Figure64).
g224406
g224406
Figure64
7.Theenginecomputercheckstheenginestate
andfaultinformation.TheInfoCentermay
displaythefollowingmessagesfoundinthe
tablethatfollows:
CheckMessageandCorrectiveActionTable
CorrectiveAction:Exittheregenerationmenuandrunthe
machineuntilthetimesincelastregenerationisgreaterthan
50hours;refertoTimeSinceLastRegeneration(page42).
CorrectiveAction:Troubleshoottheenginefaultandretry
DPFregeneration.
CheckMessageandCorrectiveActionTable
(cont'd.)
CorrectiveAction:Startandruntheengine.
CorrectiveAction:Runtheenginetowarmthecoolant
temperatureto60°C(140°F).
CorrectiveAction:Changetheenginespeedtolowidle.
CorrectiveAction:Troubleshoottheenginecomputer
conditionandretryDPFregeneration.
8.TheInfoCenterdisplaysthehomescreenand
theregenerationacknowledgeicon(Figure65)
appearsinthelowerrightcornerofthescreen
astheregenerationprocesses.
g224403
Figure65
Note:WhiletheDPFregeneration
runs,theInfoCenterdisplaysthehigh
exhaust-temperatureicon.
9.Whentheenginecomputercompletesa
parkedorrecoveryregeneration,theInfoCenter
49