Groundsmaster 4300--DPage 5 -- 44Electrical System
Service and Repairs
NOTE: See the Kubota Workshop Manual, Diesel En-
gine, 05--E3B Series at the end of Chapter 3 -- Kubota
DieselEngineforengineelectricalcomponentrepairin-
formation.
Battery Storage
If the machine will be stored for more than 30 days:
1. Remove the battery from the machine and charge it
fully (see Battery Service in this section).
2. Either store battery on a shelf or on the machine.
3. Leavecablesdisconnectedifthebatteryisstoredon
the machine.
4. Storebatteryinacoolatmospheretoavoidquickde-
terioration of the battery charge.
5. Tohelppreventthebattery fromfreezing, makesure
it is fully charged (see Battery Service in this section).
Battery Care
1. Battery electrolyte level must be properly main-
tained. The top of the battery must be kept clean. lf the
machine is stored in a locationwhere temperatures are
extremely high, the battery will discharge more rapidly
thanifthemachineisstoredinalocationwheretemper-
atures are cool.
Wear safety goggles and rubber gloves when
working with electrolyte. C harge battery in a
well ventilated place so gasses produced
while charging can dissipate. Since the gases
are explosive, keep openflames and electrical
sparks away from the battery; do not smoke.
Nauseamayresultifthegasesareinhaled.Un-
plug charger from electrical outlet before con-
necting or disconnecting charger leads to or
from battery posts.
CAUTION
IMPORTANT: Do not remove battery fill caps while
cleaning.
2. Check battery condition weekly or after every 50
hours of operation. Keep terminals and entire battery
casecleanbecauseadirtybatterywilldischargeslowly.
A. Clean batteryby washingentirecasewitha solu-
tionofbakingsodaandwater.Rinsewithclearwater.
B. Coat battery posts and cable connectors with
BatteryTerminalProtector(ToroPartNo.107--0392)
or petroleum jelly to prevent corrosion.
3. Battery cables must be tight on terminals to provide
good electrical contact.
Connecting battery cables to the wrong bat-
tery post couldresultin personal injuryand/or
damage to the electrical system.
CAUTION
4. If corrosion occurs at terminals, disconnect cables.
Always disconnect negative (--) cable first. Clean
clamps and terminals separately. Reconnect cables
withpositive(+)cablefirst.Coatbatterypostsandcable
connectors with Battery Terminal Protector (Toro Part
No. 107--0392) or petroleum jelly to prevent corrosion.
5. Check electrolyte level every 25 operating hours,
and every 30 days if machine is in storage.
6. Maintaincelllevelwithdistilledor demineralizedwa-
ter. Do not fill cells above the fill line.