NozzleDirectionSwitch(forModel44554)
g235609
Figure25
1.Nozzledirectionswitch2.T ethercontrolbox
POSITIONCLOSED
CIRCUITS
RAISEor
FORWARD
2+3,5+6
OFFNONE
LOWERor
REVERSE
2+1,5+4
Whentheleftsideofthenozzledirectionswitchispressedandheld,thenozzle
rotatesinthecounterclockwisedirection.Whentherightsideofthenozzle
directionswitchispressedandheld,thenozzlerotatesintheclockwisedirection.
Thenozzledirectionswitchislocatedonthetethercontrolbox.
TestingtheNozzleDirectionSwitch
1.Parkthemachineonalevelsurfaceandstoptheengine.
2.Disconnectthebatterynegative(-)cableatthebattery.
3.Removethetethercontrolboxcoveranddisconnectthewireharness
connectorfromtheswitch.Removetheswitchfromthecontrolboxif
necessary.
4.Useamultimeter(ohmssetting)andtheprecedingtabletodetermine
whethercontinuityexistsbetweenthevariousterminalsforeachswitch
position.
5.Replacetheswitchifnecessary.
6.Iftheswitchtestscorrectlyandacircuitproblemstillexists,checkthewire
harness;refertoAppendixA(pageA–1).
7.Installtheswitchandconnectthewireharnessaftertesting.
8.Connectthebatterynegative(-)cableatthebattery.
ProForce®DebrisBlower
Page5–21
ElectricalSystem:TestingtheElectricalComponents
18237SLRevA