g029818
Figure15
1.LEDlight5.Rotateright
2.Rotateleft
6.Increaseenginespeed
3.Decreaseenginespeed7.Enginestop
4.Enginestart
Note:Thereisatimelimitof3seconds
betweeneachbuttonpress.Ifthenextbuttonin
thesequenceisnotpressedwithin3secondsof
thelastbuttonpress,thesequenceisaborted
andmustbestartedfromthebeginning.
Ifanybuttonotherthanthenextappropriate
buttoninthesequenceispressedthesequence
isaborted.
Note:IftheSTARTbuttonisnotpressedwithin
10secondsafterpressingtheROTATERIGHT
button,oranyotherbuttonispressedinthis
period,theEngineStartEnableCondition
expires.
Note:EngineStartEnableConditionpersists
for10secondsafterpressingtheROTATERIGHT
button.
Note:PressingtheSTARTbuttondoesnot
extendthistimeperiod—themaximumlengthof
timethattheStartRelayControlcanbeactive
is10secondsfrompressingtheROTATERIGHT
button.
AftertheEngineStartEnableConditionexpires,
youmustperformtheEngineStartEnable
SequenceagaininordertoenergizetheStart
RelayControlwiththeSTARTbutton.This
cannotbeperformedfor10secondsafterthe
STARTbuttonisreleased.
Note:Ifthesequenceisabortedorthe
EngineStartEnableConditionexpires,normal
functionalityoftheROTATERIGHTandROTATE
LEFTbuttonsreturntocontroltheChuteMotor.
Important:Donotengagestarterformore
than10secondsatatime.Ifenginefails
tostartallow10secondcool-downperiod
betweenattempts.Failuretofollowthese
instructionscanburnoutstartermotor.
4.Aftertheenginestarts,movethechokecontrolto
theOFFposition.Iftheenginestallsorhesitates,
movethechokebacktotheONpositionfora
fewseconds,thensettheenginespeedtothe
desiredsetting.Repeatthisasrequired.
ShuttingOfftheEngine
1.Decreasetheenginespeedto3/4throttle.
2.PresstheSTOPbuttonontheremotecontrol.
3.Ifleavingthemachine,rotatethekeytotheOFF
positionandremoveitfromtheignitionswitch
(Figure14).
UsingtheRemoteControl
Theremotecontrolactivates(powersup)whenany
pushbuttonispressed.T oconservebatterypower,
theremotecontrolstaysactiveforapproximately3
secondsbeforeautomaticallyshuttingdownunless
thereisbuttonactivitywithinthe3secondlimit.When
theunittimesoutandpowersdown,allremotecontrol
LEDactivitystops(Figure16).Pressinganybutton
reactivatestheremotecontrol
g029818
Figure16
1.LEDlight5.Rotateright
2.Rotateleft
6.Increaseenginespeed
3.Decreaseenginespeed7.Enginestop
4.Enginestart
TheRF2CANandTEC2403controllersrevertto
PowerSaveModeifthebaseunitisinactiveformore
than2.5hourswithoutcommunicationfromtheremote
control.PowerSaveModeisalowcurrentstateof
themachine.Themachinedoesnotcommunicate
withtheremotecontrol,doesnotactivateoutputs,and
doesnotfunctionasnormal.
18