g010803
Figure10
1.Damagewilloccurhere.
7
CheckingthePTOAngle
NoPartsRequired
Procedure
Important:BeforecheckingthePTOangle,
removethetines.
1.Withtheaeratorpositionedonthegroundand
loweredtothedeepestlocation,useanangle
indictortomeasuretheanglebetweenthePTO
andtheaerator.
2.Lifttheaeratorandfullyretractthehydraulictop
linkcylinder.
3.Usinganangleindictor,checktheangle
betweenthePTOandtheaerator.
4.Ifyourmeasurementisgreaterthan35°,perform
1ofthefollowingtoadjustthetractionunitso
thatyoucannotraisetheaeratorpast35°.
•Usetheliftstopofthetractionunit(if
equipped).
•Movethelowerlinkstoahighermounting
hole(ifequipped).
8
FittingthePTOShaft
Partsneededforthisprocedure:
1
PTOshaft
Procedure
1.Parkthetractionunitandaeratoronalevel
surface.
2.Raisetheaeratorcompletelyandfullyretractthe
hydraulictoplinkcylinderorupperlink(Figure
11).
g010798
Figure11
3.Measurethedistancefromthelockinggroove
attheendofthetractionunitPTOshafttothe
lockinggrooveattheaeratorgearboxshaft
(Figure12).
Recordthismeasurementhere:
EXAMPLE:67CM(26-1/2
INCHES)
g237884
Figure12
1.Measurehere2.Lockinggroove
4.Lowertheaeratortothegroundandfullyextend
thehydraulictoplinkcylinderorupperlink
(Figure13).
13