Note:Cutoffmoreoftheinsidetubeifit
protrudesintothecrossandbearingsectionof
theoutertube.
g237888
Figure18
g237889
Figure19
14.Usingthedimensionsdeterminedinstep11,
locate,markandcutoffjustthesafetyshieldsto
exposethetubes(Figure20andFigure21).
g237890
Figure20
g237891
Figure21
15.Carefullyremoveanyburrsfromtheendsofthe
tubeswithaleandremoveallthelingsfrom
thetubes.
16.Greasetheinsidetube.
Note:Thetelescopingtubesmustalways
overlapby1/2oftheirlengthduringnormal
operationandatleast1/3oftheirlengthduring
allworkingconditions.Duringtransport,when
thedrivelineisnotrotating,thetelescoping
tubesmusthaveasuitableoverlaptomaintain
alignmentofthetubesandallowthemtoslide
freely.
9
InstallingthePTOShield
Partsneededforthisprocedure:
1
PTOshield
Procedure
1.Removethe4bolts,lockwashers,andat
washerssecuredtotherearoftheaerator
gearbox(Figure22).
g010849
Figure22
1.PTOshield
4.Bolt
2.Flatwasher5.Accesspanel
3.Lockwasher
2.MountthePTOshieldtotheaeratorgearbox
withthefastenerspreviouslyremoved(Figure
22).
Aligntheaccesspanel(Figure22)ofthePTO
shieldtothetoporthesidedependingonthe
aeratorframeconguration.