EasyManua.ls Logo

Toro Reelmaster 5410-D - Page 49

Toro Reelmaster 5410-D
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.TheInfoCenterdisplaystheINITIATINGDPF
REGENmessage(Figure83).
g224411
g227681
Figure83
6.TheInfoCenterdisplaysthetimetocomplete
message(Figure84).
g224406
g224416
Figure84
7.Theenginecomputercheckstheenginestate
andfaultinformation.TheInfoCentermay
displaythefollowingmessagesfoundinthe
tablethatfollows:
CheckMessageandCorrectiveActionTable
CorrectiveAction:Exittheregenerationmenuandrunthe
machineuntilthetimesincelastregenerationisgreaterthan
50hours;refertoTimeSinceLastRegeneration(page42).
CorrectiveAction:Troubleshoottheenginefaultandretry
DPFregeneration.
CheckMessageandCorrectiveActionTable
(cont'd.)
CorrectiveAction:Startandruntheengine.
CorrectiveAction:Runtheenginetowarmthecoolant
temperatureto60°C(140°F).
CorrectiveAction:Changetheenginespeedtolowidle.
CorrectiveAction:Troubleshoottheenginecomputer
conditionandretryDPFregeneration.
8.TheInfoCenterdisplaysthehomescreenand
theregenerationacknowledgeicon(Figure85)
appearsinthelowerrightcornerofthescreen
astheregenerationprocesses.
g224403
Figure85
Note:WhiletheDPFregeneration
runs,theInfoCenterdisplaysthehigh
exhaust-temperatureicon.
9.Whentheenginecomputercompletesa
parkedorrecoveryregeneration,theInfoCenter
49