model 2000 DeviceNet Module Manual (DN611/DN611A)
Chapter 5 Example of Use of the DN611
5
• Values for CH, UNIT, and SLOT are entered using the variables (CH, UNIT, 
SLOT) set by an initialize request.
• After slave parameter setting request processing is completed, the end con-
firmation coil END_SLAVESET turns TRUE.
(d) Operation mode control request
• When a slave node parameter setting request is completed, 
END_SLAVESET becomes TRUE, turning the start relay MODESET for the 
operation mode control setting request TRUE and starting operation.
• Values for CH, UNIT, and SLOT are entered using the variables (CH, UNIT, 
SLOT) set by an initialize request. [16#1210] is entered for SPEC to set run 
request, polling transmission enable, transmission start, and asynchronous 
mode.
• When an operation mode control request is completed, the end confirmation 
coil END_MODESET becomes TRUE,
(e) Slave data input/output
• When an operation mode control request is completed, END_MODESET 
becomes TRUE, turning the start relay ASWRITE for slave data output TRUE 
and starting operation.
• Values for CH, UNIT, and SLOT are entered using the variables (CH, UNIT, 
SLOT) set by an initialize request.  A read/write node address is entered for 
NODE.  0 is entered for BS in polling mode, or 1 BS in bit strobe mode.
• The output address to the slave device DO used here is the first of the two 
words. so if data is written in the first word (ASWRITE_DT.WDT[0]) of the 
slave data output structure ASWRITE_DT, it is output to the slave device of a 
specified address.
• When output data write is completed, the end confirmation coil 
END_ASWRITE becomes TRUE, turning the start relay ASREAD for slave 
data input TRUE and starting operation. 
Table 5-2  Slave Device Parameter Sample
Parameter Setting Name Value
N Number of requested devices 1
DEVICE[0]. First slave device setting information
  PORT   Port number 0
  SLAVEADR   Slave node address 1
  VENDOR_ID   Vendor ID 1
  P_TYPE   Product type 12
  P_CODE   Product code 1
  SCANTYPE   Scan type 1 polling
  POL_BK   Poll background 0
  BS_RCVSIZE   Bit strobe receive size 0 (byte)
  POL_REVSIZE   Polling receive size 6 (bytes)
  RESERVED1   Reserved 0 (fixed)
  POL_SNDSIZE   Polling send size 4 (bytes)
  RESERVED2   Reserved 0 (fixed)
  MAJOR_REV   Major revision 1
  MINOR_REV   Minor revision 4
  RESERVED3   Reserved 0 (fixed)
  RESERVED4   Reserved 0 (fixed)