7.3 No Run Mode
7
7.3  No Run Mode
The explanations in this section are based on the assumption that the module has started 
normally.  To change the mode from standby to run after starting the module, it is 
necessary to set the local node parameters by a parameter setting request before issuing 
an operation mode control request.  Also, clear the scan list before setting slave device 
parameters by a parameter setting request if the configuration of the slave devices is 
changed.
(1) Local node parameter setting request
Figure 7-3 Local Node Parameter Setting Request Check Items
START
Is the parameter setting 
request executed?
Yes
Yes
No
No
Execute the local node parameter setting 
request.  (See 4.3.3.)
See how to use semaphore area in 4.2.4.
Parameter setting request?
If slave device parameters have not been set yet, 
proceed to slave device parameter setting.  If they 
have already been set, proceed to operation mode 
control request.
Remove the cause of trouble 
based on completion status.
END