250 ACE-tronics G9 ASD Installation and Operation Manual
Comm2 Error CM2 External communications
error.
RS485 Failure.
Improperly programmed ASD.
Improper communications settings.
Improperly connected cables.
*Control Under-Voltage POFF Under-voltage condition at
the 5, 15, or the 24 VDC
supply.
Defective Control board.
Excessive load on power supply.
Low input voltage.
Drooping drop Encoder pulses received in
excess of F998 setting of the
opposite direction of the
commanded frequency.
Requirements of the load are in excess of the
c
apability of the motor.
Falling load.
Emergency Lift LIFT Hoist-control function
switches from closed-loop
operation to open-loop
operation. Max speed UP =
F657. Max speed DOWN =
F656.
Encoder feedback signal has been lost and
dis
crete input terminal #144 is activated or
F867 is set to Enabled.
External Fault EFLT Non-faulted ASD in a
m
ultiple ASD system.
ASD of a multiple ASD system has faulted
the non-faulted ASD(s) incur an External
Fault.
Forward Limit Switch FLS Forward Limit Switch
Ac
tivated.
Crane has approached the end-of-travel for
the selected operating plane as indicated by
the limit switch.
Heavy Load HLD Output torque requirement
ha
s exceeded the setting of
F337.
Load too heavy for motor.
Resets when output torque requirement drops
below the setting of F337
Main Under-Voltage MOFF Under-voltage condition at
the 3-phase AC input to the
ASD.
Low 3-phase utility voltage.
Maintenance Timer LTA Bearing Greaser Time has
e
xpired.
Bearing Greaser Alarm Time setting has
expired (F621).
Ambient Average Temperature Time setting
has expired (F634).
Motor Overload OLM Load requirement in excess of
t
he capability of the motor.
V/f parameter improperly set.
Motor is locked.
Continuous operation at low speed.
Load too heavy for motor.
* Reset ignored if active.
LCD Screen
LED
Screen
Description Possible Causes
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com