ACE-tronics G9 ASD Installation and Operation Manual 43
Figure 28. Startup Wizard Flow Chart.
See F986 on pg. 231 for specifics on the setup and functional
descriptions of the associated discrete input terminals for a given
Speed Control mode selection.
A (Nameplate Data)
F014 60.0 Hz
F017 On
F304 On/No OL
F402 On
F405 20 HP
F406 26.4 Amps.
F407 1750 RPM
F409 460 Volts
F426 60 Hz
F427 60 Hz
F441 150 %
F443 180 %
F990 0.5 Seconds
F991 0.5 Seconds
B (Hoist)
F009 3.0 Seconds
F010 1.5 Seconds
F113 Increase
F114F118 Unassigned N.O.
F130 Brake Fail N.O.
F132 Brake Release N.O.
F360 PG Feedback Option
F375 1024 PG PPR
F376 2Phase No.
F377 On Detect
F493 On Express Stop
F494 Off Plugging
F511 1.5 Seconds
F985 Closed-Loop Hoist
F986 2-Step Variable Volts
C (Traverse)
F009 6.0 Seconds
F010 6.0 Seconds
F015 Constant Torque
F113 Increase
F114F118 Unassigned N.O.
F130 Fault All N.C.
F132 Always Off N.O.
F360 Off
F493 Off Express Stop
F494 Off Plugging
F986 2-Step Variable Volts