88 ACE-tronics G9 ASD Installation and Operation Manual
Preset Speed 3
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 0011 and is
identified as Preset Speed 3. The binary number is applied to I1I4 of the
ACE G9-120V-PCB to output the Preset Speed (see F018 for additional
information on this parameter).
Direct Access Number — F020
Parameter Type — Numerical
Factory Default 0.0
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 4
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 0100 and is
identified as Preset Speed 4. The binary number is applied to I1I4 of the
ACE G9-120V-PCB to output the Preset Speed (see F018 for additional
information on this parameter).
Direct Access Number — F021
Parameter Type — Numerical
Factory Default 0.0
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 5
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 0101 and is
identified as Preset Speed 5. The binary number is applied to I1I4 of the
ACE G9-120V-PCB to output the Preset Speed (see F018 for additional
information on this parameter).
Direct Access Number — F022
Parameter Type — Numerical
Factory Default 0.0
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 6
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 0110 and is
identified as Preset Speed 6. The binary number is applied to I1I4 of the
ACE G9-120V-PCB to output the Preset Speed (see F018 for additional
information on this parameter).
Direct Access Number — F023
Parameter Type — Numerical
Factory Default 0.0
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 7
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 0111 and is
identified as Preset Speed 7. The binary number is applied to I1I4 of the
ACE G9-120V-PCB to output the Preset Speed (see F018 for additional
information on this parameter).
Direct Access Number — F024
Parameter Type — Numerical
Factory Default 0.0
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 3
Preset Speed 4
F020 F024