1. OUTLINE EO10-33024
1.5 ELECTRONICS SPECIFICATIONS
1- 8
3) Interface
(1) USB
1) Standard: USB V2.0
2) Transfer mode: Control transfer, Bulk transfer
3) Transfer rate: Full speed (12M bps)
4) Class Printer class
5) USB interface Connector: USB-Type B
Power: Self-power
6) USB cable Type-A and Type-B cable of USB V2.0
(2) Wired LAN
1) Standard: IEEE802.3
2) Protocol: Physical layer: 10BASE-T, 100BASE-TX
Auto negotiation 10/100Mbps. Full/Half, Duplex
Data link layer: CSMA/CD
Network layer: IP, ICMP, ARP
Transport layer: TCP, UDP
Application layer: Server: LPR, SOCKET, HTTP, FTP
Client: POP3, SMTP, DHCP, WINS
Agent: SMMP
e Network interface: Connector RJ-45
(3) RS-232C interface (Option)
1) Communication mode: Full-duplex
2) Transmission speed: 2400,4800,9600,19200, 38400, 115200 bps (selectable)
3) Asynchronous communication method
4) Transmission parameter
* Parity: None, EVEN, ODD
* Start bit: 1-bit
* Stop bit: 1-bit or 2-bit
* Word length: 7-bit or 8-bit
5) Error detection
* Parity check: VRC (Vertical Redundancy Checking)
* Framing error: This error occurs when no stop bit is found in the frame specified starting with the
start bit.
6) Data entry code: ASCII, 8-bit code for European characters, 8-bit code for graphic
7) Receiving buffer: B-EX4T: 6MB
8) Protocol
* XON/XOFF (DC1/DC3) protocol
When initialized after power on, this printer becomes ready to receive data and sends an XON code
(11H). (Transmission or non-transmission of XON code is selectable by means of the parameter
setting.)
The printer sends an XOFF code (13H) when the free area in the receive buffer becomes 10K Bytes or
less.
The printer sends an XON code (11H) when the free area in the receive buffer are 512KB or more.
When there is no free area in the receive buffer, the printer discards received data which exceeds the
receive buffer capacity without storing it in the buffer. (After detecting the XOFF code, the host
computer must stop transmission before the printer receive buffer becomes full.)
The printer sends an XOFF code (13H) at power off time. (Transmission or non-transmission of
XOFF code is selectable with the parameter setting.)
The DTR signal is always “High” level (Ready).
The RTS signal is always “High” level (Ready).
* READY/BUSY (DTR) protocol
When initialized after power on, this printer becomes ready to receive data and converts the DTR
signal to "High" level (READY).
The printer converts the DTR signal to "Low" level (BUSY) when the free area in the receive buffer
amount to 10K bytes or less.
The printer converts the DTR signal to "High" level (READY) when the free area in the receive
buffer amount to 512KB or more.

Other manuals for Toshiba B-EX4 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba B-EX4 SERIES and is the answer not in the manual?

Toshiba B-EX4 SERIES Specifications

General IconGeneral
Print TechnologyThermal Transfer / Direct Thermal
Power SupplyAC 100-240V, 50/60 Hz
Print Resolution203 dpi
Max Print Width104 mm
ConnectivityUSB, Serial, Ethernet
Media SensorTransmissive, Reflective
Media TypeRoll, Fanfold, Tag, Ticket
Media Width25.4 mm
Ribbon Width110 mm
Ribbon LengthUp to 600 m
Media Thickness0.06 – 0.19 mm