4
June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 GENERAL OPERATION
4 - 11
(E) Replace the toner cartridge ( )
(F) Developer unit not installed properly
(G) Call for service
Error code is displayed instead of the set number by pressing the [CLEAR] button and [8] button
simultaneously when the “Call for service” is blinking.
Refer to the error code table in the Service Handbook.
The 1st/2nd transport sensor and each sensors of PFP/LCF are not turned ON in a fixed period of
time after the feed clutch is turned ON
"
Paper jam (E220, E310, E320, E340–E360, E3D0 and E3E0: Error code differs depending on the
paper source.) Refer to the error code table in the Service Handbook.
Toner density becomes low
"
Auto-toner sensor detects the absence of the toner
"
Control circuit $ “Install new toner cartridge” displayed: the copying operation disabled
Solution: Open the front cover and replace the toner cartridge with a new one.
Toner is supplied $ copying operation enabled.
Disconnection of the connectors of the developer unit
"
“Developer unit not installed” is displayed.
Solution: Connect the connectors of the developer unit and close the front cover.