6
© February 2007 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO166/206
SCANNER
6 - 13
[B] Scanner top cover
[C] Scan motor (M1)
Notes:
1. Install the ADF original glass so that the
attached Mylar sheet is placed on the
front side.
2. When installing the ADF original glass,
place it between 2 small guides with its
left-hand side pushed to the scanner top
cover.
Fig. 6-10
(1) Take off the original glass.
" P.6-12 "[A] Original glass"
(2) Take off the front upper cover.
" P.2-20 "[F] Front upper cover"
(3) Take off the control panel unit.
" P.5-6 "[A] Control panel unit"
(4) Remove 8 screws and take off the scanner
top cover.
Fig. 6-11
(1) Take off the scanner top cover.
" P.6-13 "[B] Scanner top cover"
(2) Disconnect 1 connector.
Fig. 6-12
Guide
Guide
Mylar
Scanner top cover
Connector