e-STUDIO166/206 © February 2007 TOSHIBA TEC CORPORATION All rights reserved
OUTLINE OF THE MACHINE
2 - 28
[E] Switching regulator cooling fan (M6)
(1) Take off the left cover.
" P.2-19 "[C] Left cover"
(2) Disconnect 1 connector and take off the
switching regulator cooling fan while sliding it
upward.
Fig. 2-36
Switching regulator cooling fan
Connector