6F3B0253
122 T1-16S User’s Manual
7. Instructions
Forced coil
Expression
A
Input
Function
Regardless of the input sate the state of device A is retained.
Execution condition
Input Operation Output
OFF No operation
ON No operation
Operand
Name Device Register Constant Index
X Y R S T. C. XWYWRWSW T C D I J K
A Device
√√√
Example
Device Y025 retains the preceding state regardless of the devices X000 state.
X000
Y025
Set force Reset force Set force Reset force
Note
The forced coil is a debugging function. The state of a forced coil device can be set ON or OFF
by the programming tool.