206 https://www.toshiba.com/tic/
Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
Free Unit
Program Utilities Display Parameters
This parameter is used in conjunction with F702 to set the
method in which the frequency is displayed on the EOI.
The multiplier setting of F702 will be applied to the display of all
frequencies if all frequencies are selected at this parameter.
The multiplier setting of F702 will be applied to parameters F364,
F365, F367, and F368 ONLY
if PID Process Data is selected at
this parameter.
Settings:
0 — All Frequencies
1 — PID Process Data
Direct Access Number
F703
Parameter Type — Selection List
Factory Default — All Frequen-
cies
Changeable During Run — Yes
Free Unit Display Gradient Characteristic
Program Utilities Display Parameters
The ASD-displayed response to output speed changes will be
displayed as directly proportional or inversely proportional as a
function of this parameter setting.
Selecting Negative Gradient displays an increased output speed
as going more negative.
Selecting Positive Gradient displays an increased output speed
as going more positive.
Settings:
0 — Minus (Negative Gradient)
1 — Plus (Positive Gradient)
Direct Access Number
F705
Parameter Type — Selection List
Factory Default — Plus
Changeable During Run — Yes
Free Unit Display Bias
Program Utilities Display Parameters
In conjunction with the setting of F702, this parameter sets the
bias of the EOI speed display.
The frequency entered here will be multiplied by the setting of
F702 and then displayed as the zero value on the EOI display.
Direct Access Number
F706
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum Maximum Freq.
(F011)
Units — Hz
Change Step Selection 1
Program Utilities Display Parameters
In conjunction with the parameter setting of F708, this parameter
sets the amount that the output speed will increase or decrease
for each speed command change entered from the EOI using the
Rotary Encoder.
Direct Access Number
F707
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum Maximum Freq.
(F011)
Units — Hz
F703F708