EasyManua.ls Logo

Toshiba RAS-B10G3KVSG-E - Page 131

Toshiba RAS-B10G3KVSG-E
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No.
Part name Procedures
Remarks
1
Common procedure
1. Detachment
Wear gloves for this job.
Otherwise, you may injure your hands on
the parts, etc.
1) Stop operation of the air conditioner, and
turn off the main switch of the breaker for air
conditioner.
2) Remove the valve cover.
(ST
2TØ4 × 10L 2 pcs.)
After removing screw, remove the valve
cover pulling it downward.
3) Remove cord clamp (ST2TØ4 × 14L 3 pcs.),
and then remove connecting cable.
4) Remove the upper cabinet.
(ST
2TØ4 × 10L 5 pcs.)
After removing screws, remove the
upper
cabinet pulling it upward.
NOTE
Upper cabinet
Valve cover
Outdoor unit (RAS-16J2AVSG-E1)
2. Attachment
Fix the cord clamp by tightening the
screws (ST2TØ4 x 14L 3 pcs.), fitting
concave parts of the cord clamp to each
connecting cables.
Insert the upper part into the square hole
of the side cabinet, set hook claws of the
valve cover to square holes (at three
positions) of the main unit, and attach it
pushing upward,
1) Attach the upper cabinet.
(ST2TØ4 × 10L 5 pcs.)
2) Perform cabling of connecting cable,
and attach the cord clamp.
3) Attach the valve cover.
(ST2TØ4 x 10L 2 pcs.)
- 131 -