10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
Before installing the wireless remote controller
• Loading Batteries
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (-) positions.
3 Batteries
2 Wireless remote controller
Cut out a piece of SPACER from indoor
unit packaging box, roll it and insert
between the indoor unit and wall to tilt
the indoor unit for better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm or 8 mm thick heat
resisting polyethylene foam
1
3
Batteries
Flat head
wood screw
Remote control
holder
Wireless
remote control
Shield pipe
(Attach to the front panel.)
Air fi lter
Hook
Installation
plate
Hook
65 mm or more
300 mm or more
300 mm or more
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
5
Filter
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
For the rear left, bottom left and left piping
Wall
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension drain hose
(Not available, provided
by installer)
600 mm or more
100 mm or more
100 mm or more
600 mm or more
600 mm or more
2
7
4