8-2. Outdoor Unit (Inverter Assembly)
220240V ~50Hz
MICRO-COMPUTER BLOCK DIAGRAM
Driver circuit
of P.M.V.
Heat exchanger
temp.sensor
Suction temp.
sensor
Outdoor air
temp. sensor
Discharge
temp. sensor
Indoor unit
send/receive
circuit
Drive
circuit
Noise
Filter
Converter
(AC DC)
Clock
frequency
10MHz
High Power
factor Correction
circuit
High current
Detector
PWM synthesis function
Input current release control
IPM over-current detect control
Outdoor fan control
High power factor correction control
Inverter output frequency control
A/D converter function
P.M.V. control
Discharge temp. control
4-way valve control
Signal communication to indoor unit
P.M.V. : Pulse Modulating Valve
M.C.U. : Micro Controller Unit
M.C.U
For INDOOR UNIT
4-way
valve
P.M.V.
Inverter
(DC AC)
Inverter
(DC AC)
Outdoor
Fan motor
Compressor
WP-043 (P.C.B)
OUTDOOR UNIT
Current
detect
Current
detect
220
230V ~60Hz
RAS-B07G3KVSG-E, RAS-B07G3KVSGB-E / RAS-07J2AVSG-E1
RAS-B10G3KVSG-E, RAS-B10G3KVSGB-E / RAS-10J2AVSG-E1
RAS-B13G3KVSG-E, RAS-B13G3KVSGB-E / RAS-13J2AVSG-E1
- 28 -