Item Operation flow and applicable data, etc.
Description
2. Indoor fan
motor control
(Table 1) Indoor fan air flow rate
Fan speed Mode RAS-B07,B10G3KVSG-E / RAS-B07, B10G3KVSGB-E
level Cooling Heating
Cool Heat Dry Fan speed Air flow rate Fan speed Air flow rate
(rpm)
(m
3
/h)
(rpm
)
(m
3
/h)
WF UH 1030 720 980 660
WE UH H 1030 720 980 660
WD H M+ UH 980 660 900 618
WC M+ H 880 578 800 540
WB M M+ 800 540 740 460
WA M M 700 444 700 444
W9 L+ 650 394 650 394
W8 L+ L L+ 630 374 570 328
W7 L L- 550 312 550 312
W6 L- L 530 297 530 297
W5 UL UL L- 520 290 520 290
W4 UL 510
284 510 284
W3 SUL SUL/SL- 510 284 510 284
W2 SUL 500 280 510 284
W1 500 280 500 280
Fan speed Mode
RAS-B13G3KVSG-E, RAS-B13G3KVSGB-E
RAS-B16G3KVSG-E, RAS-B16G3KVSGB-E
level
Cooling Heating
Cooling Heating
Cool Heat Dry
Fan speed Air flow rate Fan speed Air flow rate
Fan speed Air flow rate Fan speed Air flow rate
(rpm)
(m
3
/h)
(rpm)
(m
3
/h)
(rpm)
(m
3
/h)
(rpm)
(m
3
/h)
WF UH
1100 788 1050
732
1120 804 1080 768
WE UH H
1100 788 1050 732
1120 804 1080 768
WD H M+ UH
1050 732 1000 668
1070 750 1030 720
WC M+ H
1000 688 900 618
1020 702 900 618
WB M M+
900 618 800 540
900 618 800 540
WA M M
800 540 700 444
800 540 750 486
W9 L+
650 394 650 394
750 486 700 534
W8 L+ L L+
630 374 580 342
700 534 600 360
W7 L L-
580 342 550 312
600 360 580 342
W6 L- L
530 297 530 297
590 350 550 312
W5 UL UL L-
520 290 520 290
540 305 540 305
W4 UL
510 284 510 284
540 305 530 297
W3 SUL SUL/SL-
510 284 510 284
530 297 520 290
W2 SUL
500 280 510 284
520 290 520 290
W1
500 280 500 280
500 280 500 280