IF08CZ10 April, 2019 - 15 -
General Specifications (Electrical)
The general (electrical) specifications of the equipment are shown in the following table.
General (Electrical) Specifications
Item Standard specification Standard
Optional
Specification
A
dditional
Optional
Specification
Remarks
Frame Sizes 2400V 0, A2, 1, B2, 3, D2, 4 See ratings table
for specific kVA
ratings available
4160V 0, A4µ, A4, A4R, B4,
B4R, 1, 2, 3, 4, G4P,
H4P, MTX15,
MTX30, MTX2-15
6600V A6S,B6S,C6S,D6S,
F6S,F6S+
Motor driven by this equipment Squirrel-cage induction motor Synchronous
motor
Main
power
supply
Input supply voltage and
range of fluctuation
Rated Voltage ±10%
(+5%/-10% for 6.9kV)
Rated Frequency ±5%
Output voltage 0 ~ Rated Voltage
Control
power
supply
Supply voltage
frequency
Internally supplied 480V, 60
Hz T300MV2, MTX 30. and
MTX2.
Internally supplied 240 V, 60
Hz MTX15.
Internally
supplied 480V,
50 Hz
T300MV2,
MTX30, &
MTX2.
Internally
supplied 240V,
50 Hz MTX15.
External
supply as an
option.
A
ll MTX series
drives require
externally
supplied space
heater power.
Main
circuit
PWM frequency 1024Hz 2400V
2048Hz 4160V
1024Hz 6600V
Regeneration system None PWM Regen is available
on select frames
only
Others Overload capacity 100% - continuous
110-115% - 60 sec (Depends
upon frame size and drive
rating)
125%,150%,
175%,200%
225%,250%
T
he higher OL
ratings require a
reduction in
continuous
capacity.
Ground protection Yes
Receptacle No
Y
es
Motor cooling fan control No
Y
es
Cabinet space heater No (indoor), Yes (outdoor)
es Space heaters
must be externally
powered.
Cabinet internal light No
Typical operating sound
levels measured at a
distance of 1m x 1.5m
high
Indoor & MTX-15 <80dBA
MTX-30 & MTX2-15 <90dBA

Table of Contents