DUST- & DRIP-PROOF TYPE SPECIFICATIONS MANUAL
When mounting the cover, apply the liquid gasket to the area shown in Fig. 5.7
above. Also, apply the Loctite adhesives to all set bolts.
!
CAUTION
When using the cutter, take careful precautions not to cut the gasket body.
DO NOT peel off the liquid gasket between the cover and gasket.
Otherwise, the dust- and drip-proof performance is damaged to cause entry
of water or dust.
Under some circumstances, the gasket may be separated from the cover.
When this happens, apply the liquid gasket to between the cover and gasket
at the time of cover mounting.
Be sure to attach the gasket and apply the liquid gasket. Also, be sure to
coat the Loctite adhesives to all set bolts. Otherwise, the dust- and
drip-proof performance is damaged to cause entry of water or dust.
Be sure to replace the gasket before it is damaged. Damaged gasket
causes the deterioration of the dust- and drip-proof performance.