Technical data
32
TOX_Manual_Process-monitoring-unit_CEP400T_en
NOTE
Avoid reversing current
Reversing current at the outputs may damage the output drivers.
On devices with field bus interface, the outputs are written on both the digi-
tal outputs and the field bus outputs. Whether the inputs are read on the
digital inputs or on the field bus inputs is selected in menu ''Additional\Com-
munication parameters/\Field bus parameters''.
Built-in version: digital outputs Q0 – Q7 (37-pin connector)
Pin OK Standard CEP
400T
CEP 200 IO (Op-
tion, see Net-
working via Ether-
net (Option), Page
21)
19 0 V 0V external 0V external
28 Q 0 OK OK
29 Q 1 NOK NOK
30 Q 2 Channel 2 OK
(only 2-channel de-
vice)
Delivery cycle
ready for measure-
ment
31 Q 3 Channel 2 NOK
(only 2-channel de-
vice)
32 Q 4 Program ACK Reserve
33 Q 5 Ready for op. Reserve
34 Q 6 Measure active Reserve
35 Q 7 Measurement in
progress channel 2
(only 2-channel de-
vice)
Reserve
36 +24V +24V external +24V external
37 +24
V
+24V external +24V external