EasyManua.ls Logo

TOX PRESSOTECHNIK CEP400T - DMS Signals

TOX PRESSOTECHNIK CEP400T
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
40
TOX_Manual_Process-monitoring-unit_CEP400T_en
4.11 DMS signals
Force measuring via DMS force transducer. The input is selected in menu
''Configuration\Force sensor configuration''(see Configuring the force sen-
sor, Page 69).
Description Value
Nominal force adjustable
see Setting Nominal Force / Nominal Dis-
tance Parameters.
Nominal stroke
A/D converter 16 bit ≙ 65536 steps
Nominal load of resolution 65536 steps, 1 step (bit) = nominal load /
65536
Gain error ±0.5 %
Max. sampling rate 2000Hz (0.5ms)
Bridge voltage 5V
Characteristic value Adjustable
Adjustment value
The entry 'Nominal force' must match the nominal value of the force sensor
used. See the data sheet of the force sensor.
4.11.1 Built-in version: pin assignment, analog standard signals
One Sub-D 15-pole female connector each (designation analog I/O) is
available for 4 measurement channels.
Pin Type
Input/Output
Analog signal
1 I Force signal 0-10 V, channel 1 / 5 / 9
3 I Ground force signal, channel 1 / 5 / 9
4 i Force signal 0-10 V, channel 2 / 6 / 10
6 I Ground force signal, channel 2 / 6 / 10
7 o Analog output 1: tare +10 V
8 o Ground
9 I Force signal 0-10 V, channel 3 / 7 / 11
10 I Ground force signal, channel 3 / 7 / 11
11 I Force signal 0-10 V, channel 4 / 8 / 12
12 I Ground force signal, channel 4 / 8 / 12
13 o Analog output 2: 0-10 V
14 o Ground
15 o +10 V sensor supply

Table of Contents