EasyManua.ls Logo

TOX PRESSOTECHNIK CEP400T - Page 69

TOX PRESSOTECHNIK CEP400T
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
69
Setting measuring cycles
F
max
F
soll
F
warn
F
min
F
warn
F
warn
= F
max
-
100%
F
max
- F
soll
*
F
warn
= F
max
+
100%
F
max
- F
soll
*
Warning limit %
Warning limit %
When the warning limit is activated the warning limit counter is raised by
value '1' after every violation of the lower and upper warning limit. As soon
as the counter reaches the value set in menu item Measuring cycles the
signal 'Warning limit reached' is set for the relevant channel. After each fur-
ther measurement the yellow symbol Warning limit message is displayed.
The counter is automatically reset when a further measuring result lies
within the set warning limit window. The counter is also reset after a restart
of the device.
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
1. Tap on the Measuring cycles input field.
w The numerical keyboard opens.
2. Enter a value between 0 and 100 and confirm with .
Configuring the force sensor
In menu ''Configuration -> Configuration of force sensor'' the parameters of
the force sensor are specified for the active process.
è Open the ''Configuration -> Force sensor configuration'' by tapping the
button in ''Configuration''.