Technical data
TOX_Manual_Process-monitoring-unit_CEP400T_en
31
Pin, D-SUB 25 OK Color code Standard CEP
400T
CEP 200 IO
(Option, see
Networking
via Ethernet
(Option),
Page 21)
19 I5 *White-yellow Offset external Test plan se-
lection cycle
20 I6 White-grey Start measure-
ment
Error reset
21 I7 White-pink Start measure-
ment channel
2 (only 2-chan-
nel device)
Reserve
13 I8 White-red HMI lock Reserve
I9 Error reset Reserve
9 I10 White-blue Program bit 4 Reserve
10 I11 *Brown-blue Program bit 5 Reserve
I12 Reserve Reserve
22 I13 *Brown-red Reserve Reserve
25 I14 Reserve Reserve
12 0 V Brown-green 0 V external
(PLC)
0 V external
(PLC)
11 0 V internal Blue 0 V internal 0 V internal
23 24 V internal Pink +24 V from in-
ternal (source)
+24 V from in-
ternal (source)
Tab.4 Wall-mounted housing: Digital inputs I0-I15 (25-pin D-sub female connector)
*25-pin line required
4.5.2 Connections
Description Value
Load voltage V
in
Rated voltage 24 V (permissible range 18
V to 30 V)
Output voltage HIGH level: min. Vin-0.64 V
LOW level: max. 100 µA · RL
Output current max. 500 mA
Parallel connection of outputs possible Max. 4 outputs with I
ges
= 2 A
Short-circuit proof Yes, thermal overload protection
Switching frequency Resistive load: 100 Hz
Inductive load : 2 Hz (dependent on in-
ductance)
Lamp load: max. 6 W
Simultaneity factor 100%
Tab.5 8 digital outputs, isolated