Analog output 1 (pin 7)
Analog output 1 supplies +10 V during measuring mode (signal 'Start
measurement' = 1).
The signal can be used to zero the measuring amplifier.
Start measurement = 1: analog output 1 = >9 V
Start measurement = 0: analog output 1: = +0 V
4.11.2 Pin assignment DMS force transducer
Only hardware model CEP400T.2X (with DMS subprint)
Pin DMS signal
1
23
4
5
6
78
9
1 Measuring sig-
nal DMS +
2 Measuring sig-
nal DMS -
3 Reserve
4 Reserve
5 Reserve
6 Supply DMS
V-
7 Sensor cable
DMS F-
8 Sensor cable
DMS F+
9 Supply DMS V
+
Tab.11 9-pole sub-D socket board DMS0 or DMS1
When connecting the DMS using the 4-conductor technique, pins 6 and 7
and pins 8 and 9 are bridged.