EasyManua.ls Logo

TOX PRESSOTECHNIK CEP400T - Log CEP 200 (Optional); Networking Via Ethernet (Option)

TOX PRESSOTECHNIK CEP400T
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
About this product
TOX_Manual_Process-monitoring-unit_CEP400T_en
21
3.3.5 Networking via Ethernet (Option)
Transfer of measuring data to the PC – Ethernet
The PC used for data acquisition can communicate with several CEP 400T
devices via the Ethernet interface. The IP address of the individual devices
can be configured (see Change the IP address, Page 89). The central PC
cyclically monitors the status of all CEP 400 devices. On termination of a
measurement, the result will be read and logged by the PC.
TOX
®
softWare Module CEP 400
The TOX
®
softWare can image the following functions:
Display and filing of measuring values
Processing and filing of device configurations
Offline creation of device configurations
3.3.6 Log CEP 200 (optional)
The CEP200 model can be replaced with a CEP400T.
To replace model CEP 200 with a CEP 400T, the CEP 200 interface must
be activated. In this case the digital inputs and outputs according to the
CEP 200 are occupied. For further information regarding handling, see the
CEP 200 manual.

Table of Contents