Technical data
38
TOX_Manual_Process-monitoring-unit_CEP400T_en
4.6 Environmental conditions
Description Value
Temperature Operation 0to + 45°C
Storage - 25to + 70°C
Relative humidity without condensation
(acc. to RH2)
5 to 90%
Vibrations according to IEC 68-2-6 15 to 57 Hz, amplitude 0.0375 mm, occa-
sionally 0.075 mm
57 to 150 Hz, acceleration. 0.5 g, occa-
sionally 1.0 g
4.7 Electromagnetic compatibility
Description Value
Immunity according to EN 61000-6-2 / EN 61131-2
Electrostatic discharge
(EN 61000-4-2)
Contact: min. 8 kV
Clearance: min. 15 kV
Electromagnetic fields
(EN 61000-4-3)
80 MHz - 1 GHz: 10 V/m 80% AM (1
kHz)
900 MHz ±5 MHz: 10 V/m 50% ED (200
Hz)
Fast transients (EN 61000-4-4) Power supply lines: 2 kV
Process digital In-outputs: 1 kV
Process analog inputs outputs: 0.25 kV
Communication interfaces: 0.25 kV
Induced high frequency
(EN 61000-4-6)
0.15 - 80 MHz 10 V 80% AM (1 kHz)
Surge voltage 1.2/50: min. 0.5 kV
(measured at AC/DC converter input)
Emission interference according to EN 61000-6-4 / EN 61000-4-5
RFI voltage EN 55011 150 kHz – 30 MHz (Group 1, Class A)
RFI emissions EN 50011 30 MHz – 1 GHz (Group 1, Class A)
Tab.10 Electromagnetic compatibility in line with EC directives