Technical data
34
TOX_Manual_Process-monitoring-unit_CEP400T_en
Wall-mounted housing: digital outputs Q0-Q7 (25-pin D-sub
female connector)
Pin, D-SUB 25 OK Color code Standard CEP
400T
CEP 200 IO
(Option, see
Networking
via Ethernet
(Option),
Page 21)
1 Q0 Red OK OK
2 Q1 Black NOK NOK
3 Q2 Yellow-brown Channel 2 OK
(only 2-chan-
nel device)
Delivery cycle
4 Q3 Violet Channel 2
NOK
(only 2-chan-
nel device)
Ready for
measurement
5 Q4 Grey-brown Program se-
lection ACK
Reserve
6 Q5 Grey-pink Ready for
measurement
Reserve
7 Q6 Red-blue Measure ac-
tive
Reserve
8 Q7 Pink-brown Channel 2
measurement
in progress
(only 2-chan-
nel device)
Reserve
12 0V Brown-green 0 V external
(PLC)
0 V external
(PLC)
24 24V White-green +24 V external
(PLC)
+24 V external
(PLC)
Tab.6 Wall-mounted housing: Digital inputs I0-I15 (25-pin D-sub female connector)
Mounting version: V-Bus RS 232
Description Value
Transmission speed 1 200 to 115 200Bd
Connecting line Shielded, min 0.14 mm²
Up to 9 600 Bd: max. 15 m
Up to 57 600 Bd: max. 3 m
Tab.7 1 channel, non-isolated