Technical data
TOX_Manual_Process-monitoring-unit_CEP400T_en
45
Outputs
Q0-Q31
Designation Field bus
byte
Field bus
bit
Q 18 Channel 6 OK 2 2
Q 19 Channel 6 NOK 2 3
Q 20 Channel 7 OK 2 4
Q 21 Channel 7 NOK 2 5
Q 22 Channel 8 OK 2 6
Q 23 Channel 8 NOK 2 7
Q 24 Channel 9 OK 3 0
Q 25 Channel 9 NOK 3 1
Q 26 Channel 10 OK 3 2
Q 27 Channel 10 NOK 3 3
Q 28 Channel 11 OK 3 4
Q 29 Channel 11 NOK 3 5
Q 30 Channel 12 OK 3 6
Q 31 Channel 12 NOK 3 7
Format of final values via fild bus (bytes 4 – 39):
The end values are written on bytes 4 to 39 on the field bus (if this function
is activated).
BYTE Designation
4 to 7 Running number
8 Process number
9 Status
10 Second
11 Minute
12 Hour
13 Day
14 Month
15 Year
16, 17 Channel 1 force [kN] * 100
18, 19 Channel 2 force [kN] * 100
20, 21 Channel 3 force [kN] * 100
22, 23 Channel 4 force [kN] * 100
24, 25 Channel 5 force [kN] * 100
26, 27 Channel 6 force [kN] * 100
28, 29 Channel 7 force [kN] * 100
30, 31 Channel 8 force [kN] * 100
32, 33 Channel 9 force [kN] * 100
34, 35 Channel 10 force [kN] * 100
36, 37 Channel 11 force [kN] * 100
38, 39 Channel 12 force [kN] * 100
Tab.13 Byte X (structure):