Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
63
Selection by Function Buttons
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
è Select process by tapping the or buttons.
Assigning Process Name
A name can be assigned for each process.
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
1. Select process.
2. Tap on process name input field.
w The alphanumeric keyboard opens.
3. Enter process name and confirm with the ↲ button.
Editing min/max limits
When setting up the process monitoring system, the parameters for the
maximum and minimum limit values must be specified in order to evaluate
the measurement values correctly.
Specifying limit values:
ü TOX
®
-Analysis assistance is available.
1. Clinching approx. 50 to 100 piece parts at simultaneous measurement
of the press forces.
2. Checking the clinching points and piece parts (control dimension 'X',
appearance of the clinching point, piece part test, etc.).
3. Analyzing the sequence of the press forces of every measuring point
(according to MAX, MIN and average value).
Determining the limit values of the press force:
1. Maximum limit value = determined max. value + 500N
2. Minimum limit value = determined min. value - 500N