TIREBOSS
TM
Tire Pressure Control
SERVICE MANUAL
2-4
f:tec\manuals\Service\SERVICEv5.indd - V6-0615
Viewer Program Installation
1. Insert TIREBOSS Viewer disk into 3 ½” Drive.
2. On Windows desktop click on “Start” button.
3. Click on “Run” and enter A:\Setup.exe
4. Click on “OK”
5. The Welcome Screen will appear; click on “Next”;
Enter your name and Company name; click on “Next”
6. The TIREBOSS Viewer, by default, sets up in the directory C:\Program Files\TireBoss Viewer.
Leave this as the destination directory and click “Next”.
7. The Start Copying Files screen will appear; if the information shown is correct click “Next”, if the
information is incorrect click “Back” and make the required changes; then click “Next”.
8. Program will install; Close the TIREBOSS Viewer screen when it appears; when complete click
“Finish”.
9. Before proceeding with the following Note, follow steps 1, 2, & 3 below and open the program to
ensure it loads and sets up the control fi les folder; Close the program before proceeding.
Note: Before beginning the next steps to use the program, the revised user fi le must be transferred to the
Control Files folder as follows: When a new fi le is sent (by e-mail) to load into the controller, right click
on the attachment & select “Save As” to save the fi le to the directory C:\Program Files\TireBoss Viewer\
Control Files. If it is replacing an existing fi le, click “Yes” when the screen is displayed asking if you want
to replace the fi le.
Pressure Setting File Loading
1. On Windows desktop click on “Start” button.
2. Click on Programs & select “TireBoss Viewer” from the list. Click on “TireBoss Viewer Icon”
3. On the TIREBOSS Viewer screen select “File” & “Open”. On the Open screen select the fi le you
want to load & click “Open”. The fi le will appear on the Viewer screen.
4. Ensure the power switch on back of controller is OFF. Plug in the 9-pin serial cable from your
computer 9-pin serial port to the 9-pin programming port on back of controller (bottom port).
5. Plug in the 2 power cables to the appropriate input plugs on back of controller (6-pin to power/
data and 4-pin to speed/ignition). Plug the 120VAC – 12VDC adapter end of power cable into a
120VAC outlet.
6. While pressing the Stop button on front of controller, turn on the power switch. Continue holding
stop button until “Begin Transfer” appears. Release Stop button.
7. On the Viewer program select “Communication” and then select “Write To Module”. “Transfer In
Process” will appear on controller. File is being transferred.
8. When the upload is completed, “Process Complete, Press Cancel to Exit” will appear on controller
& “Completed writing data to module” will appear in Viewer program. Select OK.
9. Press “Cancel” on controller and it will begin operation. Shut off power switch & remove all cables.