SO-SVN038A-EN 5
General Information
Other Required Manuals
This manual must be used with the following publications (or
their most recent versions):
CenTraVac™ Water-cooled Chillers Models CVHE, CVHF,
and CVHG With Symbio™ Controls - Installation,
Operation, and Maintenance (CVHE-SVX005*-EN)
1
CenTraVac™ Water-Cooled Chillers AdaptiView™
Display with Symbio™ Controls - User Guide
(CTV-SVU004*-EN)
1
Tracer® TU Service Tool For Water-Cooled CenTraVac™
Chillers with Symbio™ Controls - Programming Guide
(CTV-SVP004*-EN)
1
CenTraVac™ Water-cooled Chillers with Symbio™
Controls Diagnostic Descriptions, Troubleshooting Tables,
and Control Component Overview - Diagnostics Manual
(CTV-SVD005*-EN)
1
•Tracer® TU Service Tool - User Guide (BAS-SVU047*-
EN)
1
Tracer Symbio Panel Upgrade - Programming Guide
(CVRF-SVP01*-EN)
Required Tools
Normal service tools are required to perform the majority of the
work. A service technician with a well stocked tool chest should
have the right tools to perform the job.
In addition to the normal service tools and hardware, the
following is a partial list of specific field supplied hardware/
software components and special tools that are also required
to perform the display retrofit:
An RS-232 male DB9 to female DB9 pin to pin serial cable
to connect the DynaView to a PC or laptop computer.
Note: The cable must not be a null-modem cable. The
cable must be less than 50 feet in length.
The RadioShack
®
part number for the proper cable is
26-117B.
Type A to Type B USB cable to connect the Symbio 800
controller to a PC or laptop computer.
A PC or laptop computer equipped with the following:
TechView™ service software, version 12.1 or newer.
Tracer TU service software, version 2.02 or newer.
Rover™ service software (only required if the chiller is
equipped with a LonTalk
®
Comm5 board).
South pole magnet screwdriver (TOL01343).
Electronics vacuum.
Field-Provided Material
Some field provided material will be required to perform the
display retrofit. A list of material is provided here to help the
technician to plan ahead and to avoid material shortages at the
job site.
Wire, red and green #16 AWG control wire - required to
make the connections between the power supply and
existing transformer.
Wire connectors.
Wire wrap or some other form of wire protection for areas
that wiring runs may come into contact with sharp edges.
Cable ties to help clean up wiring runs.
If the unit is located outside, a cover is required for the display.
The Trane part number for this cover is COV03916.
1
A copy of this manual is shipped with the upgrade kit.

Related product manuals