Trane Tracer TD7 User Guide

Trane Tracer TD7
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
RLC-
S
VU006A-E
4
1
7
Starter Diagnostic
s
H
ex
C
o
d
e
D
ia
g
nostic Name
a
nd S
o
urc
e
E
ffect
s
T
ar
g
et
Severit
y
P
er
s
i
s
tenc
e
A
ctive M
o
des
[
Inactive Modes
]
Criteri
a
R
e
s
et
L
evel
E5
P
h
a
se Revers
a
l
C
hiller
I
mme
d
i
a
te
La
tch
C
om
p
ressor
e
ner
g
ized
t
o
tr
a
nsiti
o
n
c
ommand
[
All
Other Times
]
A
p
hase reversal was detected on the
incomin
g
current.
O
n a compressor startup
the phase reversal lo
g
ic must detect and
tri
p
in a maximum of 0.3 second from
c
om
p
ressor s
t
ar
t
.
Lo
c
al
1
8
8
S
tarter Dr
y
Run Tes
t
C
hiller
I
mme
d
i
a
te
La
tch
S
tarter Dr
y
Run
Mod
e
W
hile in the Starter Dr
y
Run Mode either
50% Line Volta
g
e was sensed at the Potential
Tr
a
nsf
o
rmers
o
r 1
0
% RLA C
u
rrent w
a
s
s
ense
d
a
t the C
u
rrent Tr
a
nsf
o
rmers.
Lo
c
al
E4
P
h
a
se L
o
ss
C
hiller
I
mme
d
i
a
te
La
tch
S
tart
S
e
q
uence
a
n
d
R
u
n m
od
e
s
a)
No current was sensed on one or two
o
f the current transformer in
p
uts while
runnin
g
or startin
g
(See Nonlatchin
g
Power
L
oss Dia
g
nostic for all three phases lost
w
hile runnin
g
). Must hold = 20% RLA.
M
ust tri
p
= 5% RLA. Time to tri
p
shall be
lon
g
er than
g
uaranteed reset on Starter
M
odule at a minimum, 3 seconds maximum.
A
ctual desi
g
n trippoint is 10%. The actual
desi
g
n trip time is 2.64 seconds. b) If Phase
reversal
p
rotection is enabled and current
is n
o
t sense
d
o
n
o
ne
o
r m
o
re c
u
rrent
x
former inputs. Lo
g
ic will detect and trip in
a
maximum of 0.3 second from com
p
ressor
sta
r
t
.
Lo
c
al
E2
M
omentar
y
P
ower
Lo
ss
C
hiller
I
mme
d
i
a
te
No
nl
a
tch
A
ll com
p
ressor
runnin
g
and
s
toppin
g
modes
[
all com
p
ressor
s
tartin
g
and non-
runnin
g
modes]
M
omentar
y
Power Loss o
p
tion disabled: No
e
ff
ec
t.
M
omentar
y
Power Loss o
p
tion enabled: A
loss of
p
ower on three line c
y
cles or more
w
as detected. Dia
g
nostic is reset in 30
s
ec
o
n
d
s.
S
ee Momentar
y
Power Loss Protection
sp
eci cation for additional information.
R
em
o
te
1
A
0
Po
wer
Lo
ss
C
hiller
I
mme
d
i
a
te
No
nL
a
tch
A
ll com
p
ressor
runnin
g
modes
[
all com
p
ressor
s
tartin
g
and non-
runnin
g
modes]
The com
p
ressor had
p
reviousl
y
established
c
urrents while runnin
g
and then all three
phases of current were lost. Desi
g
n: Less
than 10% RLA, tri
p
in 2.64 seconds. This
dia
g
nostic will preclude the Phase Loss
D
ia
g
nostic and the Transition Complete Input
Opened Dia
g
nostic from bein
g
called out.
To prevent this dia
g
nostic from occurrin
g
w
ith the inten
d
e
d
d
isc
o
nnect
o
f m
a
in
p
ower, the minimum time to tri
p
must be
g
reater than the
g
uaranteed reset time o
f
the Starter module. Note: This dia
g
nostic
prevents nuisance latchin
g
dia
g
nostics due
to a momentar
y
p
ower loss – It does not
p
rotect motor/com
p
ressor from uncontrolled
p
ower rea
pp
lication. See Momentar
y
Power
L
oss Dia
g
nostic for this protection. This
dia
g
nostic will auto reset in 10 seconds from
its occurrence, and is not active durin
g
the
s
tart mode before the transition com
p
lete
in
p
ut is
p
roven. This
p
revents the chiller from
c
yclin
g
due to some internal starter problem,
a
s the st
a
rter w
ou
l
d
l
a
tch
ou
t
o
n either
a
Starter Fault T
yp
e 3” or a “Starter Did Not
Transition” latchin
g
dia
g
nostic. However true
power loss occurrin
g
durin
g
a start would
result in a misdia
g
nosis and the chiller would
not automaticall
y
recover.
R
em
o
te
E3
S
evere
Cu
rrent
Im
ba
l
a
nce
C
hiller
No
rm
al
La
tch
A
ll Runnin
g
Modes
A
30
% c
u
rrent im
ba
l
a
nce h
a
s
b
een
d
etecte
d
o
n one phase relative to the avera
g
e of all
3
p
hases for 90 continuous seconds.
Lo
c
al
D
i
a
g
nost
i
cs

Other manuals for Trane Tracer TD7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Tracer TD7 and is the answer not in the manual?

Trane Tracer TD7 Specifications

General IconGeneral
BrandTrane
ModelTracer TD7
CategoryController
LanguageEnglish

Related product manuals