Information that can be seen on the Main Screen is:
Date and Time
Chrono activation Modality (D daily, W weekly, We week-end)
Locked buttons
User power selected or Automatic Power
Selected recipe
Functioning State System
Error code
Boiler Thermostat value
Exhaust temperature
Water temperature
Flame On if Flame Light over L01
Functioning State that can be seen on the Main Screen is :
Check Up
Preheating
Preload
Ignition Fix
Ignition
Stabilization
Run Mode
Modulation
Standby
Extinguish
Recover Ignition
Block
Other information that is presented by the display :
Out of Fuel: The message is displayed if the Pellet Sensor reads a lack
of Fuel
Cleaning: The message is displayed during the extinguishing phase
of the Start-Stop program (if this function is activated).
Prob: The message is visualized during Check Up (starting cleaning) if
one or more of the sensors is 0 °C or 0 lum (photo resistance) or if one or
more probes are unconnected or short-circuited. This is not an error, but
only a visualization .
Door: The message is displayed if the door contact is open.