6. Troubleshooting
Error Code
Er 01 Error Activation Safety Thermostat High Voltage 1
Mechanical High Limit Thermostat tripped due to high Check that boiler is completely full of water.
water temperature Check if the temperature is set too high and reduce if required.
Check that the circulation pump is working.
Re-set the manual high limit thermostat by removing the black cap
and pressing the re-set button.
Hold the ON/OFF button for 3 seconds and the error will clear.
If unsuccessfull inform Customer Service or your Local Agent
Er 02 Error Activation - Pressure Switch.
In models fitted with a pressure switch in the When closing the door check that the door makes a good seal.
combustion chamber, a lack of underpressure or Check that the exhaust fan is working.
draught will result in an error.
Hold the ON/OFF button for 3 seconds and the error will clear.
If unsuccessfull inform Customer Service or your Local Agent
Er 03 Error Activation - Pellet Thermostat High Voltage 2
Heat tavelling back through the pelletpellet feed pipe. Check that the exhaust fan is working and creating draught.
Check for any obstructions in the flue ways and clean as
necessary.
Re-set the manual reset button on the pellet feed stat on the
burner.
Hold the ON/OFF button for 3 seconds and the error will clear.
If unsuccessfull inform Customer Service or your Local Agent
Er 04 Water Over Temperature
Water temperature in the boiler has reached 95° C Check that boiler is completely full of water.
Check if the temperature is set too high and reduce if required.
Check that the circulation pump is working.
Re-set the manual high limit thermostat by removing the black cap
and pressing the re-set button.
Hold the ON/OFF button for 3 seconds and the error will clear.
If unsuccessfull inform Customer Service or your Local Agent
Cause
Remedial Measures